Cummins Diesel Generator

Short Description:

Advantages of Cummins engine: with the feature of superior performance, high combustion efficiency, fuel efficiency and can provide strong driving force, good durable(in use) economic, easy maintenance, and long continuous running, etc… As high cummins power genset, it is widely used in industrial, railway, home,generating equipments and so on. The service network of Cummins can provide customers with reliable and guaranteed service. It is welcomed by the most of customers. Alternator E...


  • EXW/FOB/CFR/CIF Price: Very Competetive, Inquiry Now!
  • Nearest Sea Port: Shanghai port, China Or other main sea port in China
  • Payment Terms: L/C or T/T
  • Supply Ability: 100 Piece/pieces per Month
  • Product Detail

    Product Tags

    Advantages of Cummins engine: with the feature of superior performance, high combustion efficiency, fuel efficiency and can provide strong driving force, good durable(in use) economic, easy maintenance, and long continuous running, etc… As high cummins power genset, it is widely used in industrial, railway, home,generating equipments and so on. The service network of Cummins can provide customers with reliable and guaranteed service. It is welcomed by the most of customers.

    Alternator

    Engine can be coupled with SUNVIM, STAMFORD, LEORY SOMER, MARATHON alternator according to customers’ demand.

    Cummins diesel generator set are ranging from 20kw up to 1200kw powered by engines series of 4B3.9, 6B5.9, 6C8.3, 6L8.9, QSZ13-G2, QSZ13-G3, NT855, MT11, KT19, KT38 and KT50 . Cummins diesel power generators are vastly used in transportation sector, buildings, telecom, schools, hospitals, ships, petrolube oil fields and industrial power supplying area etc, which can be applied as main power or backup geneator/standby generator/emergency generator.

    Controller system

    1.Standard control panel, including voltmeter, fequency meter, ampere meter,water temperature gauge, oil temperature gauge, oil pressure gauge, AMF control module,oil level indicator, emergency button,preheating button, battery voltage gauge, hours running counter for protection and tranfering.

    2.It can be with ATS electric control cabinet, including circuit breaker, LCD or LED auto controller, indicating lamp, transfer switch,etc.. Automatic transfer switch (ATS) uses update technology, which can be automatic control for on-off electricity, remote monitoring, automatic parallel operation, etc.

    50Hz Cummins Diesel Generator (diesel genset) Data Sheet (1500RPM)

    Genset Model

    Rated power

    Cummins Engine

    Marathon Alternator

    kw

    kva

    Engine Model

    Alternator Model

    ZCC20GF

    20

    25

    4B3.9-G2

    GM-20-4

    ZCC30GF

    30

    38

    4BT3.9-G2

    GM-30-4

    ZCC50GF

    50

    63

    4BTA3.9-G2

    MP-50-4

    ZCC75GF

    75

    94

    6BT5.9-G2

    MP-75-4

    ZCC90GF

    90

    113

    6BTA5.9-G2

    MP-90-4

    ZCC100GF

    100

    125

    6BTA5.9-G2

    MP-100-4

    ZCC120GF

    120

    150

    6CTA8.3-G2

    MP-120-4

    ZCC150GF

    150

    188

    6CTA8.3-G2

    MP-150-4

    ZCC160GF

    160

    200

    6CTAA8.3-G2

    MP-160-4

    ZCC200GF

    200

    250

    6LTAA8.3-G2

    MP-200-4

    ZCC200GF

    200

    250

    NT855-GA

    MP-200-4

    ZCC220GF

    220

    275

    NTA855-G1

    MP-220-4

    ZCC250GF

    250

    313

    MTAA11-G3

    MP-250-4

    ZCC250GF

    250

    313

    NTA855-G1B

    MP-250-4

    ZCC300GF

    300

    375

    NTA855-G2A

    MP-300-4

    ZCC320GF

    320

    400

    NTAA855-G7A

    MP-320-4

    ZCC350GF

    350

    438

    KTA19-G3

    MP-350-4A/S

    ZCC400GF

    400

    500

    KTA19-G3A

    MP-400-4A/S

    ZCC500GF

    500

    625

    KTAA19-G6A

    MP-500-4A/S

    ZCC600GF

    600

    750

    KTA38-GA

    MX-600-4

    ZCC720GF

    720

    900

    KTA38-G2A

    MX-720-GF

    ZCC800GF

    800

    1000

    KTA38-G5

    MX-850-4

    ZCC1000GF

    1000

    1250

    QSKTA38-G5

    MX-1030-4

    ZCC1200GF

    1200

    1500

    KTA50-GSB

    MX-1240-4

    Remarks:
    1.All above gensets are based on 50hz,400V,1500rpm,other special voltage can be satisfied.
    2.All cummins power generator can coupled with 8,12,24 hours base fuel tank.
    2.Requirement for silent generator,remote control,Synchronizing Parallel Control Panels are optional.
    3.Every generator set is subjected to a comprehensive test program which includes 50% load, 75% load
    100% load and 110% load.

    60HZ Cummins Diesel Generator (Diesel Genset) Data Sheet (1800RPM)

    Genset Model

    Rated power

    Cummins Engine

    Marathon Alternator

    kw

    kva

    Engine Model

    Alternator Model

    ZCC24GF

    24

    25

    4B3.9-G2

    GM-24-4

    ZCC30GF

    30

    37.5

    4BT3.9-G2

    GM-30-4

    ZCC50GF

    50

    62.5

    4BTA3.9-G2

    MP-50-4

    ZCC90GF

    90

    112.5

    6BT5.9-G2

    MP-90-4

    ZCC110GF

    110

    137.5

    6BTA5.9-G2

    MP-120-4

    ZCC120GF

    120

    150

    6BTAA5.9-G2

    MP-120-4

    ZCC160GF

    160

    200

    6CTA8.3-G2

    MP-160-4

    ZCC180GF

    180

    225

    6CTAA8.3-G2

    MP-180-4

    ZCC200GF

    200

    250

    6LTAA8.9-G2

    MP-200-4

    ZCC200GF

    200

    250

    NT855-GA

    MP-200-4

    ZCC250GF

    250

    313

    NTA855-G1

    MP-250-4

    ZCC300GF

    300

    375

    NTA855-G1B

    MP-300-4

    ZCC320GF

    320

    400

    NTA855-G3

    MP-320-4

    ZCC350GF

    350

    438

    KTA19-G2

    MP-350-4A/S

    ZCC400GF

    400

    500

    KTA19-G3

    MP-400-4A/S

    ZCC450GF

    450

    562

    KTA19-G4

    MP-480-4A/S

    ZCC500GF

    500

    625

    KTA19-G5

    MP-500-4A/S

    ZCC550GF

    550

    688

    KTAA19-G6A

    MX-560-4

    ZCC600GF

    600

    750

    KT38-G

    MX-600-4

    ZCC750GF

    750

    937

    KTA38-G2

    MX-750-4

    ZCC800GF

    800

    1000

    KTA38-G2A

    MX-800-4

    ZCC900GF

    900

    1125

    KTA38-G4

    MX-900-4

    ZCC1100GF

    1100

    1375

    KTA50-G3

    MX-1100-4

    ZCC1200GF

    1200

    1500

    KTA50-G9

    MX-1240-4

    Remarks:
    1.All above diesel gensets are based on 60hz,440V,1800rpm,other special voltage can be satisfied.
    2.All power generator can coupled with 8,12,24 hours base fuel tank.
    2.Requirement for silent generator,remote control,Synchronizing Parallel Control Panels are optional.
    3. Every generator set is subjected to a comprehensive test program which includes 50% load, 75% load
    100% load and 110% load.